Abstract: Aliran berayun di dalam turus bersesekat merupakan satu kaedah yang mampu meningkatkan kecekapan pencampuran bagi aliran lamina di dalam sebatang turus. Pencampuran aliran berayun dapat dicapai sekiranya aliran berayun sepenubnya merentasi plat sesekat. Walaubagaimanapun, aplikasi aliran berayun melalui turus bersesekat menyebabkan pencampuran balik berlaku di antara peringkat. Pencampuran balik akan mengurangkan keberkesanan pencampuran di dalam turus dan ia merupakan suatu kelemahan apabila aliran palam menjadi keperluan. Kajian literatur menunjukan tiada kajian yang dilakukan bagi mengkaji fenomena pencampuran balik di dalam turus bersesekat. Suatu kajian yang agak berkaitan oleh Howes dan Mackley (1990) menyebut berlakunya pencampuran balik tetapi kadar pencampuran balik dan kesan parameter operasi dan geometri ke atas pencampuran balik tiada dikaji. Oleh itu, matlamat utama kajian ini adalah menentukan magnitude pencampuran balik dan mengkaji kesan parameter operasi dan geometri ke atas pencampuran balik. Parameter-parameter yang dikaji adalah frekuensi ayunan, amplitud ayunan, kadar alir, kelikatan cecair, bukaan plat sesekat dan aplikasi turus aliran bebas bagi mengurangkan pencampuran balik. Kajian ini dimulakan dengan melakukan penyelakuan CFD aliran berayun di dalam turus bersesekat bagi menentukan corak aliran yang terbentuk di dalam turus tersebut. Penyelakuan CFD ke atas sebatang turus dengan dua peringkat telah dilakukan dengan mengunakan perisian CFD FLUENT 5.3®. Fungsi sinus digunakan untuk menyelaku suapan berayun ke dalam turus. Kajian visual menggunakan bahan pewarna yang disuntikkan pada peringkat keluaran juga dilaksanakan untuk memastikan terjadinya pencampuran balik. Seterusnya kajian makmal dilaksanakan di dalam turus menegak dua peringkat setinggi 28.2 cm dan garis pusat dalam 9.4 cm. Plat sesekat dipasangkan di dalam turus pada jarak 1.5 x garis pusat turus. Plat sesekat dengan saiz bukaan berlainan pada bahagian tengah telah digunakan di dalam kajian ini. Ayunan aliran dihasilkan oleh sebuah omboh pada bahagian bawah turus. Omboh tersebut digerakan oleh suatu sistem pneumatik. Larutan KCl dengan kepekatan tertentu digunakan sebagai bahan surih. Kadar pencampuran balik ditentukan dengan membandingkan kepekatan bahan surih dari ujikaji dengan nilai yang diperolehi dari model peringkat unggul dengan pencampuran balik (ISB) (Xu 1994). Penyelakuan CFD yang dilakukan menunjukan pencampuran balik berlaku di dalam aliran berayun melalui turus bersesekat. Kajian secara visual dengan menyuntikan bahan pewarna ke dalam turus ini mengesahkan berlakunya pencampuran balik. Hasil dari kajian makmal menunjukan model ISB sesuai digunakan bagi menentukan magnitud pencampuran balik di dalam turus bersesekat. Frekuensi dan amplitud ayunan adalah parameter operasi utama yang mempengaruhi magnitud pencampuran balik. Pencampuran balik meningkat secara eksponen dengan halaju ayunan atau hasil darab amplitud dan frekuensi ayunan. Selain itu pencampuran balik juga dipengaruhi oleh kadar alir dan sifat fizik cecair. Pencampuran balik menurun dengan kelikatan cecair dan kadar alir suapan. Pemerhatian ini adalah konsisten dengan hasil yang diperolehi oleh Xu (1994). Aplikasi turus aliran bebas bagi mengurangkan kadar pencampuran balik turut dikaji. Hasil kajian makmal mendapati aplikasi turus aliran bebas dapat mengurangkan pencampuran balik. Penurunan kadar pencampuran balik adalah berkadaran dengan (L/Do).
Abstract (other language): Oscillatory flow in baffled columns has been reported in numerous publications as very promising as a way to improve mixing, heat and mass transfer in laminar flow. Oscillatory flow mixing (OFM) can be achieved if there is fully reversing flow around baffle plates. Application of oscillatory flow in a baffled column produces a certain amount of back mixing, which is a disadvantage in a continuous system when plug flow is desired. A literature review indicates that no work has been carried out to investigate this phenomenon in oscillatory flow in a baffled column. The only related work was by Howes and Mackley (1990) in which they observed that back mixing occur in oscillatory flow in baffled column. However, the magnitude of back mixing and the effects of operating and geometric parameters were not quantified. The objectives of this work are to quantify the magnitude of back mixing and to investigate the effects of operating and geometric parameters on the back mixing rate in oscillatory flow in a baffled column. The parameters investigated in this work are oscillation frequency, oscillation amplitude, liquid flow rate, physical properties of the liquid, inter stage opening and application of draft tube to reduce back mixing rate. A computational fluid dynamics (CFD) simulation on oscillatory flow in a baffled tube was carried out at the early stage of this work to determine the flow behaviour in the column. The simulation was carried out using a commercial CFD software, FLUENT 5.3® for a two stage baffled column. The oscillating velocity was simulated using a sine function. A visual study was also carried out to verify the occurrence of back mixing by injecting a dye stuff material into the exit stage of the column. The experimental work was performed in a two-stage vertical column of 9.4 cm inner diameter and 28.2 cm height. Several baffle plates with centre opening were tested. The trials were performed with and without draft tube. A piston driven by a pneumatic system was used to oscillate the liquid. The back mixing rate was determined using the Ideal Stage with Back mixing model (ISB) (Xu 1994). The back mixing rate was determined by fitting the transient tracer data to the ISB model. The result of the CFD simulation shows that in the reverse flow, a certain amount of the liquid is back mixed into the previous stage. Visual observation using dye stuff confirms that back mixing occurs in the flow system. The results collected from this investigation indicate that the ISB model can be used to determine the magnitude of back mixing and the inter stage back mixing is significant in oscillatory flow in a baffled column. The magnitude of back mixing is dominated by oscillation frequency and oscillation amplitude. Back mixing rate increases linearly with oscillation velocity. Back mixing rate in oscillatory flow also depends on the forward flow rate. Maximum back mixing rate occurs under non-flow condition and decreases when forward flow rate is increased. Lower back mixing rate is observed in liquid with higher viscosity. This observation is consistent with the findings of Xu (1994). Application of draft tube is successful in reducing back mixing in oscillatory flow in a baffled column. The reduction in back mixing rate is proportional with the L/Do ratio.
Keywords: aliran berayun
pencirian aliran berayun
pencampuran balik
URI: http://repository.usu.ac.id/handle/123456789/4710
Appears in Collections:MT - Mechanical Engineering