    Kajian Aplikasi Pemanfaatan Efek Dingin Tanah (Ground Cooling) Untuk Pengkondisian Udara Sebuah Ruangan Dengan Luas Bangunan 68,31 m2

    Thumbnail
    View/Open
    Appendix (526.8Kb)
    Reference (467.6Kb)
    Chapter III-VI (701.6Kb)
    Chapter II (659.2Kb)
    Chapter I (476.5Kb)
    Abstract (442.3Kb)
    Cover (581.1Kb)
    Date
    2012-05-02
    Author
    Sinaga, Lobenymarkus Hezekiel
    Metadata
    Show full item record
    Abstract
    Salah satu potensi yang bisa didapatkan dari tanah adalah efek penyimpan dingin atau sering disebut groundcooling. Pemanfaatan efek groundcooling dapat dilakukan dalam banyak hal, salah satunya adalah untuk pengkondisian udara. Pada skripsi ini, efek dingin tanah (groundcooling) dimanfaatkan sebagai media pengkondisian untuk sebuah ruangan dengan luas 68,31 m2 dengan menggunakan sebuah kontainer dengan ukuran 0,65 m x 0,4 m x 0,5 m. Analisa pemanfaatan efek groundcooling ini dilakukan secara analitik dan numerik menggunakan perangkat lunak CFD. Dengan memanfaatkan efekgroundcooling, kontainer ini dapat menurunkan temperatur udara yang akan disemprotkan ke dalam ruangan hingga 3,37420 C. Penurunan temperatur ini menunjukkan bahwa efek groundcooling memiliki potensi untuk pengkondisian udara. Karena udara yang ditarik masuk ke dalam kontainer berasal dari lingkungan dan ditarik hanya dengan menggunakan sebuah blower, maka siklus ini dapat menghemat pemakaian energi listrik.
     
    One of the potency that can be obtained from the ground is the cold storage effect, or often called groundcooling. The utilization groundcooling effect can be done in many things, one of them is for air conditioning. In this minithesis, groundcooling are used as the conditioning media for a room with 68.31 m2 wide, by using a container with 0.65 m x 0,4 mx 0,5 m size. The utilization analysis for groundcooling effect is computed analytically and also numerically computation by using CFD software. By utilizing groundcooling effect, this container can make the air temperature which is squirted to the room decrease until 3.37420 C. This decreasing temperature showed that groundcooling effect has a potency for air conditioning. Because of the air which is pulled off into container to be descended from the environment, pulled off only by using a blower, so the circles can be economized electrical energy consumption.
     
    URI
    http://repository.usu.ac.id/handle/123456789/32678
    Collections
    • SP - Mechanical Engineering [755]

    University of Sumatera Utara Institutional Repository (USU-IR)
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsSubjectsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsSubjectsTypesBy Submit Date

    My Account

    LoginRegister

    University of Sumatera Utara Institutional Repository (USU-IR)
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV